Anvil combines the latest technology and most current fire protection ratings with the trusted history and manufacturing experience that have made anvil the go to source for fire protection piping products.
Clevis hanger for insulated pipe.
Tighten upper nut after adjustment.
Tighten upper nut after adjustment.
Designed for 2 of insulation on 3 4 through 1 1 2 pipe and 4 of insulation on 2 and larger pipe.
451 clevis hanger which ensures that the shield will be installed in conjunction with the hanger.
Re leveling of piping at each individual hanger after insulation is completed.
The shield is furnished with flared ends to prevent it from cutting into the insulation.
Clevis bolt spacer included as standard keeps the clevis lower strap from collapsing.
Hanger load nut above clevis must be tightened securely to assure proper hanger performance.
Also known as clevis hangers these have a pivoting loop that adjusts for line movement and vibration.
Vertical adjustment is provided varying with the size of the clevis.
Secure insulated pipe to strut channel without pinching the insulation or exposing the pipe.
It will accommodate 2 inches 51mm of insulation up to 11 2 40mm pipe and 4 inches 102mm of insulation for pipe 2 50mm and larger.
Carbon steel type 304 or 316 stainless steel upon request.
Hanger load nut above clevis must be tightened securely to assure proper hanger performance.
Designed for the suspension of insulated stationary pipe lines.
They are recommended for the suspension of non insulated stationary pipe lines.
The elongated design permits the insulation to encompass the hanger while maintaining a clearance between the insulation and the cross bolt.
Eaton offers a wide variety of b line series clevis hangers to suspend and support insulated and non insulated pipe while allowing vertical adjustment and limited movement.
Vertical adjustment without removing pipe may be made from 3 8 through 5 1 8 varying with the size of clevis.
Costly calcium silicate inserts.
Specify size number pipe size insulation thickness figure number name and finish.
This allows the installation of the insulation to be more economical due to the fact that less cutting and fitting is required.
When an oversized clevis is used a pipe spacer should be placed over the cross bolt to assure that the lower u strap will not move in on the bolt.
455 is a combination of our fig.
Wood blocks and standard shields.
160 shield welded to a fig.
A clevis hanger is a pipe attachment providing vertical adjustment consisting of a clevis type top bolted to a formed steel bottom strap.
Designed for the suspension of stationary insulated pipe lines.