The airflow from the soffits to the ridge vent keeps the roof cool and prevents ice dams and the material will block that flow.
Continuous insulation on attic eave wall.
The 2015 irc requires r 49 insulation for ceilings with attic spaces.
For the same reason insulation shouldn t touch the roof s underside.
Ensure meets any eaves insulation and or internal wall insulation to prevent cold bridge at eaves without blocking any ventilation paths required to loft space roof space.
So much information has been devoted to the subject of roof venting that it s easy to become confused and to lose focus.
Design the roof to allow full insulation over the top plates of the exterior walls.
Install raised heel trusses or use another roof framing method that allows space to install insulation over the top plates of the exterior walls or install high density insulation to achieve an r value that meets or exceeds code minimums for attic insulation.
Gables to be insulated as exterior walls.
Flexible formaldehyde free glass mineral wool.
Figure 3 unvented roof assembly at eave retrofitted with rigid foam spray foam and taped top edge of existing house wrap or building paper to seal the top of wall to roof transition while spray foam is installed to the underside of roof sheathing to floor sheathing to inside face of rigid insulation backing and to inside face of existing wall sheathing to insulate and air seal the attic.
What is continuous insulation.
So i ll start by saying something that might sound controversial but really isn t.
Covering up the soffit vents with loose fill or batts which can happen if you stuff insulation along the eaves is a huge no no.
Climate zones 1 5 and 8 16 wall assemblies must not exceed a maximum u factor of 0 051 climate zones 6 7 wall assemblies must not exceed a maximum u factor of 0 065 mineral wool performance attic.
A vented attic where insulation is placed on an air sealed attic floor is one of the most underappreciated building assemblies that we have in the history of building science.
Unlike typical insulation installed between framing members continuous insulation provides an uninterrupted thermal barrier for unparalleled performance.
85 minimum to bs en iso 14021.
Continuous insulation products can also serve as the water resistant barrier and air barrier for a structure providing a 3 in 1 building envelope solution.
Insulation cover should be even and continuous right to the eaves.
However there is an exception.
Attic insulation unvented attics must be air sealed at roof deck eaves gables and penetrations.